Eaton BR vs CH Breakers: Cutler-Hammer Breaker Types Explained
Eaton makes two plug-on residential breaker lines, Type BR and Type CH, and many people still know both by the Cutler-Hammer name. They look similar but they aren't interchangeable. Here's how to tell them apart, which one your panel takes, and the other Eaton breaker types you'll run into.
Shopping now? Shop Eaton BR breakers, Eaton CH breakers or all Eaton Cutler-Hammer breakers.
BR vs CH at a glance
| Type BR | Type CH | |
|---|---|---|
| Width per pole | 1 inch | ¾ inch |
| Fits | BR load centers | CH load centers |
| Interrupting rating | 10, 22 or 42 kAIC, depending on the model | 10 kAIC at 120/240V (standard CH breakers) |
| Eaton warranty | 10 years | Lifetime |
| Model numbers start with | BR (for example BR120) | CH (for example CH120) |
| Fits the other type's panel? | No | No |
Specifications are from Eaton's published comparison of BR and CH breakers.
The difference that matters: width
Eaton lists BR breakers at 1 inch wide per pole and CH breakers at ¾ inch. Because they're different sizes and built for different load centers, a BR breaker won't fit a CH panel and a CH breaker won't fit a BR panel. Use the breaker type listed on your panel label.
How to tell which type your panel takes
- Read the label inside the panel door. It lists the breaker types the load center is designed for, such as BR or CH.
- Read a breaker's model number. BR breakers start with BR; CH breakers start with CH.
- Look at the handles. Eaton describes CH breakers as black with sandalwood (tan) handles.
- Check the width. A single-pole BR breaker is 1 inch wide; a single-pole CH breaker is ¾ inch.
Why do panels say Cutler-Hammer?
Eaton bought Cutler-Hammer in 1978 and sold breakers under the Cutler-Hammer name for years afterward, so many panels and breakers still carry it. A Cutler-Hammer BR or CH breaker and an Eaton BR or CH breaker are the same product line.
Other Eaton breaker types
- BR AFCI, GFCI and dual function. The letters at the end of the model number mark the protection: AF for arc fault (BRP120AF), GF for ground fault (BRP120GF) and DF for dual function (BRP120DF).
- CH AFCI and GFCI, such as the CHFP115AF arc fault breaker and the CHFN230GF double-pole GFCI.
- BAB bolt-on breakers, such as the BAB1020, which bolt on rather than plug on, for panelboards that call for bolt-on breakers.
- Quad breakers, such as the BQC220230, which put two double-pole breakers in one unit.
- Tandem breakers, such as the DNBA1515, which put two single-pole circuits in one space. See what is a tandem breaker.
Quads and tandems go only in the panel spaces the label allows.
Reading an Eaton model number
Most Eaton model numbers give the type, then the number of poles, then the amps:
- BR120: Type BR, single-pole, 20 amp.
- BR230: Type BR, double-pole, 30 amp.
- BR2100: Type BR, double-pole, 100 amp.
Plug-on neutral
Eaton makes plug-on neutral versions of some BR and CH breaker types for load centers with a neutral rail. Check that your panel has the rail before ordering a plug-on neutral breaker.
FAQ
Can I put a BR breaker in a CH panel?
No. BR breakers are 1 inch per pole and CH breakers are ¾ inch, and each is made for its own load centers.
Is Cutler-Hammer the same as Eaton?
Yes. Eaton bought Cutler-Hammer in 1978. Cutler-Hammer BR and CH breakers are Eaton breakers.
Which is better, BR or CH?
For a replacement, your panel decides. When a new panel goes in, CH is more compact and carries Eaton's lifetime warranty, while BR comes in more interrupting ratings. Your electrician can recommend one.
Who should install the breaker?
Breakers go inside a live electrical panel. Have a licensed electrician install them.