Square D QO120 20 amp single-pole QO circuit breaker

Square D QO vs Homeline: What's the Difference?

⚠️ Safety Disclaimer: The information in this article is intended for educational purposes only. Electrical work can be dangerous and may be subject to local codes and regulations. Always consult a licensed electrician before performing any electrical work in your home. Flaretek is not responsible for any injury, damage, or code violations resulting from the use of this information.

Square D, Schneider Electric's breaker brand, makes two residential breaker lines: QO and Homeline. They look alike and both plug on to the panel, but they're built for different load centers and they are not interchangeable. The short answer: buy the line your panel is labeled for.

Shopping now? Shop QO breakers or shop Homeline breakers.

QO vs Homeline at a glance

QO Homeline
Width per pole ¾ inch 1 inch
Fits Square D QO load centers Square D Homeline load centers
Model numbers start with QO (for example QO120) HOM (for example HOM120)
Standard interrupting rating 10kA 10kA
Plug-on neutral versions Yes (for example QO120PAF) Yes (for example HOM120PDFC)
AFCI, GFCI and dual function Yes Yes
Fits the other line's panel? No No

The difference that matters: size and fit

A QO breaker is ¾ inch wide per pole. A Homeline breaker is 1 inch wide per pole. The two lines use different bus designs, and Schneider Electric states that each breaker type fits only its own load center. The one exception is the QOM series of main breakers, which both QO and Homeline load centers use.

Schneider Electric also says QO and Homeline load centers are listed to accept only Square D breakers, and that installing another manufacturer's breaker voids the UL listing and the warranty. So a Siemens or Eaton breaker doesn't belong in either panel, even if it seems to fit.

How to tell which panel you have

  1. Read the label inside the panel door. It lists the breaker types the load center is designed for, such as QO or HOM.
  2. Read a breaker's model number. It's printed on the breaker: QO120 is a QO breaker, HOM120 is a Homeline breaker.
  3. Check the width. A single-pole QO breaker is ¾ inch wide; a single-pole Homeline breaker is 1 inch.
  4. Look for a trip window. QO breakers have a Visi-Trip indicator, a small window that shows when that breaker has tripped.

If the label is missing or unreadable, don't guess. Have an electrician identify the panel before you buy breakers for it.

What QO offers

  • Visi-Trip indication, so you can see which breaker tripped.
  • A more compact size: ¾ inch per pole.
  • Bolt-on versions. QOB breakers (for example the QOB220) are the bolt-on version of QO, for panelboards that call for bolt-on breakers.
  • DC ratings on many models. Schneider Electric lists QO breakers such as the QOB2100 and QO1515 for DC systems up to 48V DC.
  • Tandem models, such as the QO1515 and QO1520, which put two circuits in one space in load centers that accept them.

What Homeline offers

  • A full residential range. We carry Homeline breakers from 15 to 200 amps, plus AFCI, GFCI, dual function and HOMT tandem and quad models.
  • Homeline surge protection. The HOM2175SB SurgeBreaker plugs on to Homeline load centers, and the HOM250PSPD is a Homeline plug-on neutral surge protector.
  • A lower price than the matching QO breaker in most cases.

Which is better?

For a replacement breaker, it isn't your choice: your panel decides. A Homeline panel takes Homeline breakers and a QO panel takes QO breakers.

The choice only comes up when a new panel goes in. Then it's a trade-off: QO is more compact and has Visi-Trip, while Homeline usually costs less. Both are UL listed Square D products with the same 10kA standard interrupting rating. Your electrician can recommend one for your home.

Reading a Square D model number

Square D model numbers give the series, then the number of poles, then the amps, then any options:

  • QO120: QO, single-pole, 20 amp.
  • HOM230: Homeline, double-pole, 30 amp.
  • QOB2125: QO bolt-on, double-pole, 125 amp.
  • GFI at the end means GFCI, CAFI or PAF means combination arc fault (AFCI), and DFC or PDFC means dual function.
  • A P after the amps marks plug-on neutral: the QO120PCAFI is plug-on neutral, while the QO120CAFI has a pigtail wire.

FAQ

Can I put a Homeline breaker in a QO panel?

No. Homeline breakers are 1 inch per pole and QO spaces are ¾ inch, and Schneider Electric says each breaker type fits only its own load center.

Can I put a QO breaker in a Homeline panel?

No, for the same reason. Use Homeline breakers in a Homeline load center.

Do QO and Homeline panels use the same main breaker?

Schneider Electric says QOM-series main breakers are the one exception: both QO and Homeline load centers use them.

Can I use a Siemens or Eaton breaker in a Square D panel?

No. Schneider Electric says QO and Homeline load centers are listed for Square D breakers only, and other brands void the UL listing and warranty.

Who should install the breaker?

Breakers go inside a live electrical panel. Have a licensed electrician install them.