Collection: Dual Function AFCI/GFCI Breakers

A dual function breaker combines AFCI arc fault protection (against fire) and GFCI ground fault protection (against shock) in one breaker, so a circuit that needs both takes a single panel space. We carry dual function breakers for Square D QO and Homeline, Siemens, Eaton BR, ABB (GE) and Leviton load centers.

How to choose a dual function breaker

When you need one

NEC sections 210.8 (GFCI) and 210.12 (AFCI) both list kitchens and laundry areas, so those circuits often need both kinds of protection. A dual function breaker does that in one device instead of an AFCI breaker plus GFCI outlets. Which NEC edition applies depends on your state or city, and your local inspector has the final say.

Match the breaker to your panel

A breaker only fits the load centers it's listed for, so start with the label inside your panel door. Square D makes two separate lines: QO breakers are ¾ inch wide per pole and Homeline breakers are 1 inch, and Schneider Electric says neither fits the other's load center.

Your panel Models we carry
Square D QO QO115DFC, QO120DFC (pigtail); QO115PAFGF, QO120PAFGF (plug-on neutral)
Square D Homeline HOM115DFC, HOM120DFC (pigtail); HOM115PDFC, HOM120PDFC, HOM115PAFGF, HOM120PAFGF (plug-on neutral)
Siemens Q120DF, Q115DFN, Q120DFN, Q115DFP
Eaton BR BRN115DF, BRN120DF, BRP115DF, BRP120DF
ABB (GE) Q-Line THQL1115DF, THQL1120DFP, THQL1120PDF
Leviton LB115-DFT, LB120-DFT

Plug-on neutral or pigtail?

Plug-on neutral breakers clip onto a neutral rail in load centers built for them, with no neutral wire to connect. Pigtail breakers have a coiled white wire that goes to the panel's neutral bar, for load centers without that rail. In Square D model numbers, a P after the amp rating marks plug-on neutral: the QO120PCAFI is plug-on neutral, while the QO120CAFI has a pigtail. For other brands, the product title says when a model is plug-on neutral.

Amps

Replace a breaker with the same amperage and number of poles as the one it replaces. The breaker's amp rating is set by the wire on the circuit, so never put in a bigger breaker than the wire is rated for.

Installation

Breakers are installed inside a live electrical panel. Have a licensed electrician do the work.

FAQ

Is a dual function breaker the same as an AFCI breaker?

No. An AFCI breaker only detects arcing. A dual function breaker detects arcing and ground faults. Compare them in AFCI vs GFCI breakers.

Can I use a dual function breaker where only AFCI is required?

Yes, as long as it's listed for your load center and matches the circuit's amperage.

Where can I shop single-function breakers?

See our AFCI breakers and GFCI breakers.

About this collection

A dual function breaker combines AFCI arc fault protection (against fire) and GFCI ground fault protection (against shock) in one breaker, so a circuit that needs both takes a single panel space. We carry dual function breakers for Square D QO and Homeline, Siemens, Eaton BR, ABB (GE) and Leviton load centers.

How to choose a dual function breaker

When you need one

NEC sections 210.8 (GFCI) and 210.12 (AFCI) both list kitchens and laundry areas, so those circuits often need both kinds of protection. A dual function breaker does that in one device instead of an AFCI breaker plus GFCI outlets. Which NEC edition applies depends on your state or city, and your local inspector has the final say.

Match the breaker to your panel

A breaker only fits the load centers it's listed for, so start with the label inside your panel door. Square D makes two separate lines: QO breakers are ¾ inch wide per pole and Homeline breakers are 1 inch, and Schneider Electric says neither fits the other's load center.

Your panel Models we carry
Square D QO QO115DFC, QO120DFC (pigtail); QO115PAFGF, QO120PAFGF (plug-on neutral)
Square D Homeline HOM115DFC, HOM120DFC (pigtail); HOM115PDFC, HOM120PDFC, HOM115PAFGF, HOM120PAFGF (plug-on neutral)
Siemens Q120DF, Q115DFN, Q120DFN, Q115DFP
Eaton BR BRN115DF, BRN120DF, BRP115DF, BRP120DF
ABB (GE) Q-Line THQL1115DF, THQL1120DFP, THQL1120PDF
Leviton LB115-DFT, LB120-DFT

Plug-on neutral or pigtail?

Plug-on neutral breakers clip onto a neutral rail in load centers built for them, with no neutral wire to connect. Pigtail breakers have a coiled white wire that goes to the panel's neutral bar, for load centers without that rail. In Square D model numbers, a P after the amp rating marks plug-on neutral: the QO120PCAFI is plug-on neutral, while the QO120CAFI has a pigtail. For other brands, the product title says when a model is plug-on neutral.

Amps

Replace a breaker with the same amperage and number of poles as the one it replaces. The breaker's amp rating is set by the wire on the circuit, so never put in a bigger breaker than the wire is rated for.

Installation

Breakers are installed inside a live electrical panel. Have a licensed electrician do the work.

FAQ

Is a dual function breaker the same as an AFCI breaker?

No. An AFCI breaker only detects arcing. A dual function breaker detects arcing and ground faults. Compare them in AFCI vs GFCI breakers.

Can I use a dual function breaker where only AFCI is required?

Yes, as long as it's listed for your load center and matches the circuit's amperage.

Where can I shop single-function breakers?

See our AFCI breakers and GFCI breakers.