Siemens QP QF240A 40 Amp Double-Pole 120/240V GFCI Circuit Breaker
Regular price $95.99 USDRegular priceSale price $95.99 USD -
Square D Homeline HOM215GFI 15 Amp Double-Pole 120/240V GFCI Circuit Breaker
Regular price $110.00 USDRegular priceSale price $110.00 USDSold out -
Square D Homeline HOM220GFIC 20 Amp Double-Pole 120/240V GFCI Circuit Breaker
Regular price $99.99 USDRegular priceSale price $99.99 USDSold out -
Square D Homeline HOM115DFC 15 Amp Single-Pole 120V Dual-Function AFCI/GFCI Circuit Breaker
Regular price $52.99 USDRegular priceSale price $52.99 USD -
Square D QO QO230GFI 30 Amp Double-Pole 120/240V GFCI Circuit Breaker
Regular price $64.99 USDRegular priceSale price $64.99 USD -
Siemens QP Q215GF 15 Amp Double-Pole 120/240V GFCI Circuit Breaker
Regular price $125.00 USDRegular priceSale price $125.00 USDSold out -
Eaton CH CHFN250GF 60A Double-Pole 120/240V GFCI Circuit Breaker
Regular price $189.99 USDRegular priceSale price $189.99 USDSold out -
Square D Homeline HOM115PAFGF 15 Amp Single-Pole Dual-Function AFCI/GFCI Plug-On Neutral Circuit Breaker
Regular price $55.00 USDRegular priceSale price $55.00 USDSold out -
Siemens QP QF245A 45 Amp Double-Pole 120/240V GFCI Circuit Breaker
Regular price $119.00 USDRegular priceSale price $119.00 USD -
Square D QO QO115GFI 15 Amp Single-Pole 120V GFCI Circuit Breaker
Regular price $56.99 USDRegular priceSale price $56.99 USDSold out -
GE THQB1115GFT 15 Amp Single-Pole 120V GFCI Bolt-On Circuit Breaker
Regular price $113.99 USDRegular priceSale price $113.99 USDSold out -
GE , THQB1120GFT - 20 Amp GFCI Circuit Breaker, Bolt-On - 20 Amp - 1 Pole - 120 Volt
Regular price $89.99 USDRegular priceSale price $89.99 USDSold out -
Leviton LB115-DFT 15 Amp Single-Pole Plug-On AFCI/GFCI Circuit Breaker
Regular price $73.78 USDRegular priceSale price $73.78 USDSold out -
Leviton LB120-DFT 20 Amp 1-Pole Plug-On AFCI/GFCI Circuit Breaker
Regular price $68.78 USDRegular priceSale price $68.78 USDSold out -
ABB Q-Line® THQL1115DF 15 Amp Single-Pole 120V Dual-Function AFCI/GFCI Circuit Breaker
Regular price $67.00 USDRegular priceSale price $67.00 USDSold out -
GE THQL1120PAF2 20 Amp Single-Pole 120V Dual-Function AFCI/GFCI Circuit Breaker
Regular price $45.00 USDRegular priceSale price $45.00 USD
About this collection
A GFCI (ground fault circuit interrupter) breaker protects people from electric shock. It trips when it detects current leaking to ground, for example through water or a person, and protects the whole circuit from the panel. We stock single-pole and double-pole GFCI breakers for Square D QO and Homeline, Siemens, Eaton BR and CH, and ABB (GE) load centers.
How to choose a GFCI breaker
Match the breaker to your panel
A breaker only fits the load centers it's listed for, so start with the label inside your panel door. Square D makes two separate lines: QO breakers are ¾ inch wide per pole and Homeline breakers are 1 inch, and Schneider Electric says neither fits the other's load center.
| Your panel | Models we carry |
|---|---|
| Square D QO | QO115GFI, QO120GFI (single-pole); QO230GFI, QO240GFI, QO250GFI, QO260GFI (double-pole) |
| Square D Homeline | HOM115GFI, HOM120GFI (single-pole); HOM215GFI, HOM220GFIC, HOM230GFIC, HOM240GFI, HOM250GFIC (double-pole) |
| Siemens | QF115A, QF120A, QF115AN, QF120AN (single-pole); QF215, QF220A, QF230A, QF240A, QF245A, QF250A, QF260A, Q215GF, Q220GF, Q230GF, Q230GFN (double-pole) |
| Eaton BR | BRP120GF, BRN120GF (single-pole); BRN230GF, BRN240GF, BRN250GF (double-pole) |
| Eaton CH | CHFN230GF, CHFN240GF |
| ABB (GE) Q-Line | THQL1120GFTP, THQL2150GFT; THQB bolt-on models |
Single-pole or double-pole?
Single-pole GFCI breakers protect 120 volt circuits. Double-pole GFCI breakers protect 240 volt or 120/240 volt circuits and take two spaces. Replace a breaker with the same amperage and number of poles as the one it replaces. The breaker's amp rating is set by the wire on the circuit, so never put in a bigger breaker than the wire is rated for.
Plug-on neutral or pigtail?
Plug-on neutral breakers clip onto a neutral rail in load centers built for them, with no neutral wire to connect. Pigtail breakers have a coiled white wire that goes to the panel's neutral bar, for load centers without that rail. In Square D model numbers, a P after the amp rating marks plug-on neutral: the QO120PCAFI is plug-on neutral, while the QO120CAFI has a pigtail. For other brands, the product title says when a model is plug-on neutral.
GFCI breaker or GFCI outlet?
A GFCI breaker protects every outlet and device on the circuit and resets at the panel. A GFCI outlet protects itself and anything wired after it, and resets at the outlet. We carry both: shop GFCI outlets.
How sensitive is a GFCI?
Class A GFCIs, the type used to protect people, trip at a ground-fault current of a few milliamps; Schneider Electric rates its Homeline models to trip above 6 mA.
Where GFCI protection is required
NEC section 210.8(A) requires GFCI protection for many receptacles in homes, including bathrooms, kitchens, garages, outdoors, crawl spaces, basements, laundry areas and areas near sinks. If the circuit also needs AFCI protection, use a dual function AFCI/GFCI breaker. Which NEC edition applies depends on your state or city, and your local inspector has the final say. See also GFCI breakers for bathrooms.
Installation
Breakers are installed inside a live electrical panel. Have a licensed electrician do the work.
FAQ
What is a GFCI breaker?
A breaker with built-in ground fault protection. Read more in what is a GFCI breaker and do you need one.
Why does my GFCI breaker keep tripping?
Common causes are moisture, appliance leakage and wiring faults. See why a GFCI breaker keeps tripping.
Are GFI and GFCI the same thing?
Yes. GFI (ground fault interrupter) and GFCI (ground fault circuit interrupter) are two names for the same protection.
Does a GFCI breaker also protect against overloads?
Yes. A GFCI breaker also gives the overload and short-circuit protection of a standard breaker.
How do I test a GFCI breaker?
Press its TEST button; the breaker should trip. Step by step: how to test a GFCI breaker.